• Compare
My Account
  • Orders
  • Compare
  • Log In/Register

Check out our live Google reviews

  • No products in the cart.
Water Heater Brokers
Call our water heating brokers now

0800 692 672

Main menu
  • Home
  • About us
    • About Us
    • Brochure Download
      • Bosch
      • Rheem
      • Rinnai
    • Testimonials
    • Google Review
  • Installations
  • Products
    • Gas Water Heating
      • Bosch
      • Rheem
      • Rinnai
    • Electric Water Cylinders ddd
      • Mains Pressure
        • Bosch
        • Rheem
        • Rinnai
      • Low Pressure
        • Bosch
        • Rheem
        • Rinnai
      • Installation Deals
        • Bosch
        • Rheem
        • Rinnai
    • Central Heating
      • Bosch
      • Rheem
      • Rinnai
    • Heat Pump Water Heating
      • Bosch
      • Rheem
      • Rinnai
    • Commercial
      • Bosch
        • Professional Series
        • Manifold Packs
        • Worcester Condensing Boilers
      • Rheem
      • Rinnai
    • Valves
      • Rmc
      • Apex
    • Components
      • Bosch
      • Rheem
      • Rinnai
      • Other
    • Controllers
      • Bosch
      • Rheem
      • Rinnai
  • My News
  • Contact
    • Support FAQs
    • Live Chat
  • START HERE
  • Home
  • Gas Appliance Wiki
  • Error Codes on a Rheem 27

Error Codes on a Rheem 27

RANK Comments Off on Error Codes on a Rheem 27 22 Oct 2019

Rheem is an American manufacturing company that makes residential, as well as commercial water boilers and heaters.  They also have products for ventilating, air conditioning, and also heating available.

Rheem 27

Focusing on the Rheem 27, this is a water heater with the highest capacity continuous flow gas water heater. This is called the 27 because it has a 27L/minute capacity, which delivers extra hot water should the need arise.  This product is perfect for large families where a large amount of hot water is needed but with a small space.  This has several features and includes:

  • A capacity of 27 Liters
  • It can be used by up to 4 to 6 people
  • Lastly, it has an energy rating of 6.

Troubleshooting Rheem Tankless Error Codes

Troubleshooting a tankless water heater could appear confusing but if you get to know what the error codes mean, it could become an easy task although having a wireless monitoring or app is a great help in identifying issues with your Rheem tankless water heaters.  There are issues that can be fixed by yourself but some would need professional help to get it fixed. However, should you be in a situation where an error code is displayed, the first thing that you should do is turning off your water tap, then do the same to the remote control, wait for at least 5 minutes before turning it on again and lastly open the hot water faucet. If there are no changes and an error code is still displayed, then what should be done is close off the hot water tap and the remote should be turned off.  You can also use the error guidelines listed but we recommend calling a technician so that any problem can be checked thoroughly and professionally.

 

 

List of Tankless Water Heater Error Codes

Error Code 1L There may be deposits of Limescale or scale in the heat exchanger, which causes for water flow to

reduce and the temperature to increase.

To address this, you should  descale the water heater flush the heat exchanger wherein one must check with the owner’s manual for complete instructions.

Error Code 05 This could be because of a blockage in the air supply pipe or the exhaust vent. Another thing to check is that the connection or termination may be loose or incorrectly done.  The unit may still operate but you may hear an alarm sound every 60 seconds when the tap is open.

The venting system should be checked for problems or what is blocking the vent should be removed if you are having problems finding the cause; a professional service should be called.

It should also be noted that the vent system was done according to requirements and that the fan motor should be checked as well.

Error Code 10 Blower motor could not be working properly or a false flame has been detected.

What to do in a case such as this is to ensure that all vent and heat exchange components are clean and are connected properly.  Fuel inlet and exhaust should be free of blockage and one has to make sure that the proper vent materials are used.

One should also make sure that the maintenance is up to date.

Error Code 11 There is no ignition which could be because of gas supply or installation error.

This could also be because the gas shut-off valve is not completely open.

To address this, one has to make sure that the gas pipe is open. The gas type, pressure and volume should be checked and one should make sure that they match the system’s requirements.

The air in the gas line should be emptied and that the gas line, regulator and meter are the right size.

Connections should be checked and made sure that the unit is accurately grounded.

Error Code 12 There is a flame failure or the heater can’t maintain a flame.

This could be because of having not enough gas because of an interruption in gas supply from the distributor if you are using natural gas and a tankless water heater.  If propane gas is used, you must make sure that you have enough gas in your propane tank.

Error Code 13 There may be indoor venting where a flame rod warns of poor and improper combustion.

In cases like these, you can consult the owner’s manual  or you can contact a professional.

Have the proper installation requirements wherein the intake and exhaust vents meet the requirements thus ensuring a safety operation.

Error Code 14 The overheat wrap is experiencing problems or fault.  This could be due to maintenance error or flue pipe is overheating.

The mid-efficiency and condensing units have faults in the Overheat Limiter (OHL).

One has to make sure that the proper gas type is being used and the high fire and low fire manifold pressures are correct.

Cracks or openings should be checked including air flow restrictions around the vent terminal and unit.

A foreign object may also be present in the combustion chamber and exhaust pipe work.

Error Code 15 When you get an error code 15 this means a boiling safety warning.

This could be because the water tap is not fully opened therefore water flow is low which causes excessive temperature of the heat exchanger.

One should check that the cold water inlet pipe and inlet valve is fully open and also one has to make sure there is no blockage.

Error Code 16 This is a warning on excessive temperature where heater has already exceeded safe water heat levels.

One has to make sure that the outlet water is not above preset thermostat settings.

In cases such as this, it should be checked that the combustion chamber, exhaust pipes, heat exchanger and vent terminal have no blockages.

Error Code 21 The air intake filter intake switch is malfunctioning.

One has to make sure that the air filter door is seated properly and there should be correct installation of the front panel.

Error Code 24 The Error Code 24 means there is a malfunction in the operational switch.

In cases such as these, the unit should be restarted, connections should be checked.

In cases where even after the button is reset and it still doesn’t work, the PCB should be replaced.

Error Code 29 This is telling you that there could be a clogged neutralizer.  It could also be that the heat  exchanger output temperature is too low.

If this appeared it could be that the heat exchanger air inlet needs to be cleaned.

One has to make sure that the drain line is not blocked and if everything still does not work, a technician should be called.

Error Code 31 When Error Code 31 is seen, there could be a problem with the water inlet temperature sensor.

If this is seen, the sensor wiring should be checked for any damages and scales should be cleared.

Error Code 33 There could be issues with the outgoing water temperature sensor.

The sensors should be checked for wire damages and scales should be cleaned off.  One should Ohm out the sensor. If necessary, the sensors should be replaced.

Error Code 34 Issues in the temperature combustion air temperature sensor for example the wiring.

The sensors should be cleared of scales and checked for damages.

It should be made sure that there are no restrictions to the air flow and that the fan blades should be in good shape and tightly attached to the motor shaft.

Just like with Error Code 33, Ohm out the sensor and a replacement should be done if deemed necessary.

Error Code 35 There is incorrect connection with the thermistor.

Make sure there is proper connection between the thermistor and the control board.

Error Code 51 If you are seeing Error Code 51, this means that there is a problem with the gas control valve.

The gas control valve should be Ohm out and one should check for any loose or damaged terminals to the wiring of the gas control valves.

Error Code 52 This means that there are problems with the PFGR (Proportional Gas Flow Regulating) valve.

Ohm out the valve and then it should be checked for any loose or broken connections.

Error Code 61 There is a failure of the combustion fan.

Make sure that there is no damage to the wiring harness or motor and that all connections are tight.

There should be minimal resistance when fan motor is turning and the length of the venting should also be checked.

Error Code 71 There is a problem with the gas solenoid valve control.

The gas inlet solenoid valve wiring harness should be checked for damages or loose terminals and ohm out the valve.

Error Code 72 Issues with the flame sensing device.

This could be because of an issue with the flame rod therefore it should be made sure that there is no damage to the wiring and that it is providing the proper voltage.

The burner chamber should be clear from any blockages.

Error Code76 There is an error with regards to the communication of the remote control.

Make sure that there are no damaged or loose connections and in worst cases, the remote control may need to be replaced.

Error Code 79 There is a problem with the fan motor current.

One should make sure that there is minimal resistance when the fan motor is turning and that the motor is receiving the proper voltage.

In worst cases, the fan motor or the PCB may need to be replaced.

Error Code 80 and 81 There is failure in gas cut-off.

The voltage of every flame rod should be checked and Ohm out the solenoid valves.  If it becomes necessary the gas control valve needs to be replaced.

Error Code 82 There is a problem determining the gas type which could be because the control board is not programmed properly.

The PCB should be programmed to the proper gas type and that one should make sure that there is proper installation.

Error Code 99 This means that the blower motor is not venting or the flue could be blocked.

Blockages should be checked and then cleared in the combustion fan, exhaust flue, heat exchanger and then the inlet filter.

We would recommend that a qualified person opens the appliances or attempts a repair.  These are only to provide you with information and serve as a guide to help identify the fault.  In case your are having doubts, you can give Water Heater Brokers NZ (Water Heater Brokers) a ring.  We have installed water heaters for years and that our staff have the necessary experience and skill to assist your needs from start to completion of the work.  Just get in touch with us if you have any questions.

 

My Blog Categories

  • Birkenhead (1)
  • Central Heating (3)
  • Electric Water Storage (2)
  • Gas Appliance Wiki (1)
  • Gas Water Heating (14)
  • General Talk (5)
  • Heat Pump Water Heating (3)
  • Installations (13)
  • Rheem (5)
  • Rinnai (6)
  • Uncategorized (2)

View Installations

  • Did You Get Your Water Heater Deal In Auckland? In the last 3 months Water Heater Brokers has installed…
  • Before And After Of A Rinnai Instantaneous Replacement We sent our resident gas installer on a simple mission…
  • Another Successful Rheem Gas 27 When you are looking for a new continuous flow gas…

Top rated products

  • Bosch Highflow 26e $2,799.00 Product price: $1,552.50 incl GST
  • Bosch Internal Compact Ci16 $3,109.00 Product price: $1,515.00 incl GST
  • Bosch Condensing 5000w 18kW $3,999.00 Product price: $2,629.00 incl GST
  • Bosch External HydroPower 10H $1,800.00 Product price: $1,599.00 incl GST
  • Bosch Commercial 32C $5,509.00 Product price: $4,729.00 incl GST

Recent Reviews

  • BOSCH PILOT IGNITION 16P
    Rated 5 out of 5
    by Water Heater Brokers
  • Rheem Stellar NG A850360
    Rated 5 out of 5
    by Terry
  • Rinnai VT 26EXT LPG INFVT26L
    Rated 5 out of 5
    by James M
  • Bosch External HydroPower 10H
    Rated 5 out of 5
    by David L
  • Bosch Highflow 26e
    Rated 5 out of 5
    by John

Delivering the latest technology in water heating to New Zealand homes. Water Heater Brokers products are invented, engineered and manufactured for life.

Our primary focus is to deliver innovation in products that are built to the latest EU efficiency standards and quality assurances.

Useful Link

  • Request a Quote
  • Cost Adviser
  • Contact Us
  • Products
  • Blog
  • Testimonials
  • Live Chat
  • Terms And Conditions

Categories

  • Gas Water Heating
  • Central Heating
  • Heat Pump Water Heating
  • Commercial
  • Components

My Facebook Page

Water Heater Brokers
© waterheater.co.nz Webdesign by YHP and powered by Search Engine Ninja.

CLOSE

  • <
  • 1
  • 2
  • 3
  • 4
  • 5
  • >

For more information, please call us:

0800 692 672 chat now

Step one

Select your application and click NEXT

Our smart online adviser will help you get the information or price you need in no time! Simply follow our simple six step process and receive your quote within 2 hours, during business days.

Step two

Wanting to replace or upgrade to a Continuations gas system??

Water Heater Broker specializes in continuous gas hot water systems. Whether you are needing your current gas appliance serviced or upgraded Water Heater Broker can provide design and installation services at n unmatched service and price. Hot water cylinder leaking? Its the perfect time to consider gas! Save money on running costs and enjoy endless hot water. Combine our gas water systems with Heat pumps, solar or Wetback.

Need your hot water cylinder replaced or repaired?

Water Heater Broker now provides hot water cylinder services. We can replace or repair your existing hot water cylinder. This includes mains and low pressure systems. We offer Enamel and Stainless steel solutions. Combine our water storage with Heat pumps, solar or Wetback. Design services also available.

Whether existing or new, Water Heater Broker does it all.

Whether you are building new or retrofitting your existing home, Bosch central heating systems are superior in technology and price for value. Our technical team will look at your requirements and design a system that is not under or over specified accommodating your budget. Our services include servicing of existing central heating systems, design and installation of new systems for retrofits or new homes

Save up to 60% on your water heating bill with Water Heater Broker.

Water Heater Broker specializes in heatpump and solar technology. Our heat pump range applies to a multitude of applications, including domestic water heating, underfloor Heating, pool heating and a series of combination systems. Whether you are renovating or building new, Water Heater Broker will provide you with a key turn solution for your home or business.

Step three

If available, give us an idea on layout, plans and images can be attached.

To give you an accurate price or recommendation, please provide as much information as possible. This includes floor plans for existing homes or engineered plans for new builds. Our technical team will then be able to provide an engineered solution to your requirements. Got nothing? Simply press next to move forward.

Step four

Urgent or not, Water Heater Broker will respond quickly.

Please note that our QS team is very busy hence, we would appreciate an indication of urgency for your requirements. Regardless of urgency we endeavour to respond within 2 working hours. All quotes are free of charge and subject to our policies.

Step five

Just a few more details and you are done!

We just need a few more details to finalise your enquiry. Once submitted our team will get onto it right away! depending on your requirements we will provide a design and quote within 2 working hours (up to 24 hours max). We do not save your details and you will not receive any advertising material (spam) from Water Heater Broker. Thank you for contacting Water Heater Broker.

Continue with Facebook
NEXT
PREV
NEXT
PREV
NEXT
PREV
NEXT
PREV
NEXT
This is optional, just click next to continue.
PREV
NEXT
PREV
NEXT
PREV
SUBMIT

Your enquiry has been submitted.

THANK YOU FROM
WATER HEATER BROKERS.

Share on Facebook

0800 692 672